Sign In | Join Free | My himfr.com
Home > MTL Safety Barrier >

MTL 5541 Repeater Power Supply 20-35VDC DIN Rail

GREAT SYSTEM INDUSTRY CO. LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MTL 5541 Repeater Power Supply 20-35VDC DIN Rail from wholesalers
     
    Buy cheap MTL 5541 Repeater Power Supply 20-35VDC DIN Rail from wholesalers
    • Buy cheap MTL 5541 Repeater Power Supply 20-35VDC DIN Rail from wholesalers
    • Buy cheap MTL 5541 Repeater Power Supply 20-35VDC DIN Rail from wholesalers
    • Buy cheap MTL 5541 Repeater Power Supply 20-35VDC DIN Rail from wholesalers
    • Buy cheap MTL 5541 Repeater Power Supply 20-35VDC DIN Rail from wholesalers
    • Buy cheap MTL 5541 Repeater Power Supply 20-35VDC DIN Rail from wholesalers

    MTL 5541 Repeater Power Supply 20-35VDC DIN Rail

    Ask Lasest Price
    Brand Name : MTL
    Model Number : MTL5541
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 100+pc+on stock
    Delivery Time : on request
    • Product Details
    • Company Profile

    MTL 5541 Repeater Power Supply 20-35VDC DIN Rail

    Quick Detail of Repeater Power Supply

    Manufacturer : MTL Instruments
    Product No. : MTL5541
    Product Type : Repeater Power Supply
    Number of channels : One
    Location of transmitter : Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location
    Safe-area circuit ripple : < 50µA peak-to-peak
    Transfer accuracy at 20°C : Better than 15µA
    Temperature drift : < 0.8µA/°C
    Response time : Settles to within 10% of final value within 50µs
    Communications supported : HART® (terminals 1 & 2 only)
    LED indicator : Green: power indication
    Maximum current consumption (with 20mA signal) : 51mA at 24V
    Dimensions (LxWxH) : 1.58 cm x 10.98 cm x 12.36 cm
    Weight : 0.11 Kg


    Description of Repeater Power Supply

    The MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load.


    Specification of Repeater Power Supply

    Hazardous Area InputSignal range: 0-24 mA (including over-range); Transmitter voltage: 16.5 V at 20 mA
    Safe Area OutputSignal range: 4-20 mA; Under/over-range: 0-24 mA; Load resistance: 0 to 360Ω @ 24 mA, or 0 to 450Ω @ 20 mA; Current sink: 600Ω max.; Maximum voltage source: 24 VDC; Output resistance: > 1 MΩ
    Power Requirement20-35 VDC.
    Response TimeSettles to within 10% of final value within 50 µs
    Current Consumption51 mA @ 24V
    Maximum Power Dissipation0.7 W @ 24 VDC, 1.0 W @ 24 VDC
    Isolationn 250 V RMS, tested at 1500 V RMS minimum, between safe-area and hazardous-area terminals; 50 V between safe-area circuits and power supply
    Transfer Accuracy at 68°F (20°C)Better than 15 µA
    LED IndicatorGreen: Power indication
    Temperature LimitsOperating: -6 to 140°F (-20 to 60°C); Storage: -40 to 176°F (-40 to 80°C)
    Temperature Drift< 0.8µA/°C
    Humidity5 to 95% RH
    MountingT-section 35 mm DIN rail (7.5 or 15 mm) to EN 50022
    TerminalsAccommodate up to 2.5 mm2 stranded or single-core
    Safety DescriptionVo= 28 V, Io= 93 mA, Po= 651mW, Um= 253 RMS or DC
    Weight150g

    Advantage of Our Team

    • Best possible prices and delivery time
    • Long time experience in the field
    • Well trained staff
    • Own warehouse facilities
    • Best relationships with branch office of manufacture
    • Flexible and individual service for you
    • Cheap and safe forwarder for shipments (air)

    Quality MTL 5541 Repeater Power Supply 20-35VDC DIN Rail for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: GREAT SYSTEM INDUSTRY CO. LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)